Review




Structured Review

alcon inc intraocular lens acrysof® iq aspheric iol
Intraocular Lens Acrysof® Iq Aspheric Iol, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/acrysof+iols/acrysof+iq+aspheric+iol/pm40565876-62-11-16
Average 90 stars, based on 1 article reviews
intraocular lens acrysof® iq aspheric iol - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

In Vitro:

Article Title: A narrative review of intraocular lens opacifications: update 2020
Article Snippet: .. van der Mooren et al. ( 84 ) , 5 AcrySof IOLs (Alcon Laboratories Inc, Forth Worth, Texas, USA) , Glistenings were induced in vitro . , The number of microvacuoles per cubic mm in AcrySof lenses ranged from 46 to 3,862; iSymm IOLs ranged from 2,545 to 6,495; enVista IOLs 3 to 6; Tecnis lenses ranged from 12 to 36. .. , 3 iSymm IOLs (HOYA Surgical Optics Inc, Singapore), , Microvacuole particle size distribution and particle volume density was measured using confocal light microscopy and dark field microscopy, the corresponding extinction coefficient γ was determined , The MV in the enVista IOLs had an effective diameter of approximately 33 ìm and in the Tecnis IOLs 25 ìm while the sizes in the iSymm IOLs and AcrySof IOLs were significantly smaller, 5.2 and 6.2 ìm, respectively.

other:

Article Title: Light scattering levels from intraocular lenses extracted from donor eyes.
Article Snippet: Methods: Light scattering in 74 donor IOLs was measured with the C-Quant device adapted for in vitro analysis of IOLs.. Straylight was assessed at a 2.5-degree and 7.0-degree scatter angle, and results were compared with the straylight of a 20-year-old crystalline lens, a 70-year-old crystalline lens, and a lens with cataract.. To identify potential changes to the IOL material, the IOLs were examined with a light microscope and a slitlamp.

Article Title: A narrative review of intraocular lens opacifications: update 2020
Article Snippet: A high amount of glistenings developed in most SN60WF IOLs, while only few ZCB00 IOLs displayed a low degree of glistenings Chang et al. ( 83 ) 80 patients: 40 AcrySof SA60AT (1-piece IOL group); 40 a Sensar AR40e (3-piece IOL group) 5 to 7 years postoperatively, retroillumination images were obtained and the PCO area and severity were evaluated using computer software There were no significant differences in PCO between the 2 groups High-contrast (100%) and low-contrast (2.5%) CDVA were measured The 3-piece IOL group had significantly fewer glistenings (P<0.001) Scheimpflug images were obtained to evaluate glistenings, which were quantified objectively by digital image analysis using computer software There was correlation between the subjective grading of glistenings and objective computer-processed image grading The glistenings were not correlated with IOL power, CDVA, or CS Thomes et al. ( 82 ) AcrySof Natural IOLs Model SB30 AL (n=100) manufactured in 2003 Glistenings were induced in vitro Glistenings were present in all lenses after the accelerated microvacuole test method AcrySof Natural IQ Model SN60 WF IOLs (n=270) manufactured in 2012 Image analysis program was used to evaluate glistenings The mean microvacuole density for IOLs manufactured in 2003 was 315.7 microvacuoles per square millimeter (MVs/mm 2 ) with a glistening severity less than 100 MVs/mm 2 in 1.0% of the IOLs The mean microvacuole density for IOLs manufactured in 2012 was 39.9 MVs/mm 2 with a glistening severity less than 100 MVs/mm 2 in 95.2% of the IOLs Laboratory-induced microvacuole density was significantly lower in IOLs manufactured in 2012 (mean 39.9 MVs/mm 2 ) relative to IOLs manufactured in 2003 (mean 315.7 MVs/mm 2 ) as indicated by the Wilcoxon test of significance (P<0.0005) Miyata et al. ( 35 ) 24 eyes received AcrySof SN60WF IOL before manufacturing improvement Light scattering on the anterior IOL surface was examined up to 3 years postoperatively using an EAS-1000 anterior segment analyzer After the improvement, the IOLs showed no increase in surface light scattering up to 2 years, a significant increase was found at 3 years (P<0.001) 27 eyes received AcrySof SN60WF IOL after improvement The CDVA and CS under photopic and mesopic conditions were also examined 3 years postoperatively The light scattering with the improved IOL was significantly reduced at all observations (P<0.048) No difference was found in the CDVA and CS van der Mooren et al. ( 84 ) 5 AcrySof IOLs (Alcon Laboratories Inc, Forth Worth, Texas, USA) Glistenings were induced in vitro .

Control:

Article Title: Clinical and material degradations of intraocular lenses: A review.
Article Snippet: .. Control of the polymerization process, to make it as uniform as possible, appears to play a role,32 with surface scattering and glistenings formation found to be more significant with IOLs manufactured by cast moulding than by lathe cutting.32 In order to reduce the occurrence of glistenings in AcrySof IOLs, Alcon Laboratories Inc. altered the manufacturing process in the early 2010s, implementing tight environmental and process controls in the formulation, cast moulding and curing operations.37,38 Subsequently, Miyata et al.37 found that surface light scattering due sub-surface nanoglistenings was significantly reduced and Thomes and Callaghan38 found that the percentage of IOLs with glistenings, induced in the laboratory, with a density of >100/mm2 was 99% in the 2003 AcrySof IOL models and only 4.8% in AcrySof IOLs manufactured in 2012. ..

Formulation:

Article Title: Clinical and material degradations of intraocular lenses: A review.
Article Snippet: .. Control of the polymerization process, to make it as uniform as possible, appears to play a role,32 with surface scattering and glistenings formation found to be more significant with IOLs manufactured by cast moulding than by lathe cutting.32 In order to reduce the occurrence of glistenings in AcrySof IOLs, Alcon Laboratories Inc. altered the manufacturing process in the early 2010s, implementing tight environmental and process controls in the formulation, cast moulding and curing operations.37,38 Subsequently, Miyata et al.37 found that surface light scattering due sub-surface nanoglistenings was significantly reduced and Thomes and Callaghan38 found that the percentage of IOLs with glistenings, induced in the laboratory, with a density of >100/mm2 was 99% in the 2003 AcrySof IOL models and only 4.8% in AcrySof IOLs manufactured in 2012. ..



Similar Products

86
Vivity Labs Inc acrysof iq vivity iol
Acrysof Iq Vivity Iol, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/acrysof+iols/acrysof+iq+vivity/pmc13123711-198-3-5
Average 86 stars, based on 1 article reviews
acrysof iq vivity iol - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
Vivity Labs Inc toric iols acrysof
Toric Iols Acrysof, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/acrysof+iols/acrysof+iq+vivity+iol/pm40661044-29-14-15
Average 90 stars, based on 1 article reviews
toric iols acrysof - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Vivity Labs Inc intraocular lens (iol) acrysof iq
Photopic binocular uncorrected VAs at 3 to 6 months after bilateral implantation of <t>IOL</t> with monovision, as per surgery type. IOL = <t>intraocular</t> lens; logMAR = logarithm of the minimum angle of resolution; RLE = refractive lens exchange; SD = standard deviation; VA = visual acuity.
Intraocular Lens (Iol) Acrysof Iq, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/acrysof+iols/acrysof+iq+vivity+iol/pmc12187150-38-12-19
Average 90 stars, based on 1 article reviews
intraocular lens (iol) acrysof iq - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Vivity Labs Inc acrysof iq vivity edof iol
Mean monocular logMAR visual acuity with best correction for distance based on the vergence chart for <t>AcrySof</t> IQ Vivity) intraocular lens <t>(IOL)</t> at 6 months post-surgery. The error bars show the standard deviation. The right y-axis shows the Snellen visual acuity in feet and the top x-axis is the distance (cm). Depth-of-focus was defined as the range of lens powers that achieved a mean acuity of 20/32 or better (from 0 D of vergence).
Acrysof Iq Vivity Edof Iol, supplied by Vivity Labs Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/acrysof+iols/acrysof+iq+vivity+iol/pmc12203608-37-18-20
Average 90 stars, based on 1 article reviews
acrysof iq vivity edof iol - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
alcon inc intraocular lens acrysof® iq aspheric iol
Mean monocular logMAR visual acuity with best correction for distance based on the vergence chart for <t>AcrySof</t> IQ Vivity) intraocular lens <t>(IOL)</t> at 6 months post-surgery. The error bars show the standard deviation. The right y-axis shows the Snellen visual acuity in feet and the top x-axis is the distance (cm). Depth-of-focus was defined as the range of lens powers that achieved a mean acuity of 20/32 or better (from 0 D of vergence).
Intraocular Lens Acrysof® Iq Aspheric Iol, supplied by alcon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/acrysof+iols/acrysof+iq+aspheric+iol/pm40565876-62-11-16
Average 90 stars, based on 1 article reviews
intraocular lens acrysof® iq aspheric iol - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Photopic binocular uncorrected VAs at 3 to 6 months after bilateral implantation of IOL with monovision, as per surgery type. IOL = intraocular lens; logMAR = logarithm of the minimum angle of resolution; RLE = refractive lens exchange; SD = standard deviation; VA = visual acuity.

Journal: Journal of Cataract and Refractive Surgery

Article Title: Visual and participant-reported outcomes of a wavefront-shaping EDOF intraocular lens implanted bilaterally with monovision

doi: 10.1097/j.jcrs.0000000000001636

Figure Lengend Snippet: Photopic binocular uncorrected VAs at 3 to 6 months after bilateral implantation of IOL with monovision, as per surgery type. IOL = intraocular lens; logMAR = logarithm of the minimum angle of resolution; RLE = refractive lens exchange; SD = standard deviation; VA = visual acuity.

Article Snippet: To report visual and participant-reported outcomes after bilateral implantation of nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity) with monovision correction during cataract or refractive lens exchange (RLE) surgery.

Techniques: Standard Deviation

Visual disturbances a at 3 to 6 months after bilateral implantation of IOL with monovision as per surgery type. IOL = intraocular lens; RLE = refractive lens exchange. a Over the last 7 days, have you experienced problems with your vision and how severe, if yes?

Journal: Journal of Cataract and Refractive Surgery

Article Title: Visual and participant-reported outcomes of a wavefront-shaping EDOF intraocular lens implanted bilaterally with monovision

doi: 10.1097/j.jcrs.0000000000001636

Figure Lengend Snippet: Visual disturbances a at 3 to 6 months after bilateral implantation of IOL with monovision as per surgery type. IOL = intraocular lens; RLE = refractive lens exchange. a Over the last 7 days, have you experienced problems with your vision and how severe, if yes?

Article Snippet: To report visual and participant-reported outcomes after bilateral implantation of nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity) with monovision correction during cataract or refractive lens exchange (RLE) surgery.

Techniques:

Photopic binocular uncorrected VAs at 3 to 6 months after bilateral implantation of IOL with levels of monovision a . IOL = intraocular lens; SD, standard deviation; VA = visual acuity. a Low monovision: myopic eye >−0.75 D and ≤−0.50 D; medium monovision: myopic eye >−1.00 D and ≤−0.75 D; high monovision: myopic eye ≤−1.00 D.

Journal: Journal of Cataract and Refractive Surgery

Article Title: Visual and participant-reported outcomes of a wavefront-shaping EDOF intraocular lens implanted bilaterally with monovision

doi: 10.1097/j.jcrs.0000000000001636

Figure Lengend Snippet: Photopic binocular uncorrected VAs at 3 to 6 months after bilateral implantation of IOL with levels of monovision a . IOL = intraocular lens; SD, standard deviation; VA = visual acuity. a Low monovision: myopic eye >−0.75 D and ≤−0.50 D; medium monovision: myopic eye >−1.00 D and ≤−0.75 D; high monovision: myopic eye ≤−1.00 D.

Article Snippet: To report visual and participant-reported outcomes after bilateral implantation of nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity) with monovision correction during cataract or refractive lens exchange (RLE) surgery.

Techniques: Standard Deviation

Visual disturbances at 3 to 6 months after bilateral implantation of IOL with levels of monovision a . IOL = intraocular lens. a Over the last 7 days, have you experienced problems with your vision and how severe, if yes?

Journal: Journal of Cataract and Refractive Surgery

Article Title: Visual and participant-reported outcomes of a wavefront-shaping EDOF intraocular lens implanted bilaterally with monovision

doi: 10.1097/j.jcrs.0000000000001636

Figure Lengend Snippet: Visual disturbances at 3 to 6 months after bilateral implantation of IOL with levels of monovision a . IOL = intraocular lens. a Over the last 7 days, have you experienced problems with your vision and how severe, if yes?

Article Snippet: To report visual and participant-reported outcomes after bilateral implantation of nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof IQ Vivity) with monovision correction during cataract or refractive lens exchange (RLE) surgery.

Techniques:

Mean monocular logMAR visual acuity with best correction for distance based on the vergence chart for AcrySof IQ Vivity) intraocular lens (IOL) at 6 months post-surgery. The error bars show the standard deviation. The right y-axis shows the Snellen visual acuity in feet and the top x-axis is the distance (cm). Depth-of-focus was defined as the range of lens powers that achieved a mean acuity of 20/32 or better (from 0 D of vergence).

Journal: Frontiers in Medicine

Article Title: Visual outcomes with a non-diffractive enhanced depth-of-focus IOL in patients with age-related macular degeneration

doi: 10.3389/fmed.2025.1505401

Figure Lengend Snippet: Mean monocular logMAR visual acuity with best correction for distance based on the vergence chart for AcrySof IQ Vivity) intraocular lens (IOL) at 6 months post-surgery. The error bars show the standard deviation. The right y-axis shows the Snellen visual acuity in feet and the top x-axis is the distance (cm). Depth-of-focus was defined as the range of lens powers that achieved a mean acuity of 20/32 or better (from 0 D of vergence).

Article Snippet: The aim of this clinical prospective study was to provide more clinical evidence on the use of the AcrySof IQ Vivity EDOF IOL in a series of eyes diagnosed with AMD and implanted with this model, through measuring visual acuity at different distances and assessing visual function using two patient-reported outcome questionnaires.

Techniques: Standard Deviation